MODEL | LRS-150-5 | LRS-150-12 | LRS-150-15 | LRS-150-24 | LRS-150-36 | LRS-150-48 | |
OUTPUT | DC Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Current | 22A | 12.5A | 10A | 6.5A | 4.3A | 3.3A | |
Current Range | 0~22A | 0~12.5A | 0~10A | 0~6.5A | 0~4.3A | 0~3.3A | |
Rated Power | 110W | 150W | 150W | 156W | 154.8W | 158.4W | |
Ripple &Noise | 100mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
Voltange ADJ. Range | 4.5~5.5V | 10.2~13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V | |
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup, Rise Time | 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load | ||||||
Hold Up Time | 16ms/230VAC 12ms/115VAC at full load | ||||||
INPUT | Voltage Range | 85 ~ 264VAC 120 ~ 373VDC | |||||
Frequency Range | 47 ~ 63Hz | ||||||
Efficiency | 85% | 87.5% | 89% | 89% | 89% | 90% | |
AC Current | 2.8A/115VAC 1.6A/230VAC | ||||||
Inrush Current | CCOLD START 60A/230VAC | ||||||
Leakage Current | <0.75mA/ 240VAC | ||||||
Protection | Over Load | 110 ~ 140% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
Over Voltage | 5.75~6.75V | 13.8~16.2V | 18.75~21.75V | 28.8~33.6V | 41.4~48.6V | 55.2~64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
Environment | Working Temp. | -20 ~ +70ºC (Refer to "Derating Curve") | |||||
Working Humidity | 20 ~ 90% RH non-condensing | ||||||
Storage Temp.,Humidity | 40 ~ +85 , 10 ~ 95% RH | ||||||
Temp.Coefficien | ±0.03%/ºC (0~50ºC) | ||||||
Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
Safety&EMC | Safety Standards | EN60950-1, EN60335-1, EN61558-1 2 16 approved | |||||
Withstand voltage | I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/70% RH | ||||||
Others | MTBF | 648.6K hrs min. MIL-HDBK-217F (25ºC) | |||||
Dimension | 159*97*30mm (L*W*H) | ||||||
Packing | 0.48kg |
The LRS-150 series from Winston is a versatile power supply unit suitable for a variety of applications. Here are some specific use cases:
The LRS-150 series is known for its high efficiency, compact size, and wide operating temperature range, making it a popular choice for many applications where a 150W power supply is needed. It also comes with a 3-year warranty, indicating the manufacturer's confidence in its reliability .
When using the LRS-150 power supply, observe the following precautions to ensure safety and optimal performance:
1. Follow Correct Installation Procedures: Before installation, carefully read and follow the product manual and installation guide from Winston Electric.
2. Ensure Proper Ventilation: As the LRS-150 is naturally ventilated, it is important to ensure adequate air circulation for heat dissipation.
3. Avoid Over-voltage: Make sure the input voltage is within the range specified by the power supply to avoid damage or reduced performance.
4. Pay Attention to Load Requirements: Do not exceed the power supply's rated load, as this could damage the power supply or shorten its service life.
5. Handle Power Cords Correctly: Ensure that power cords are connected correctly to avoid short circuits or poor contacts.
6. Check for Withstand Voltage and Insulation: In high voltage or humid environments, pay special attention to the product's withstand voltage and insulation performance.
7. Note the Operating Temperature: The LRS-150 can operate in a temperature range of -30°C to +70°C, but please avoid exceeding these limits.
8. Avoid Vibration and Impact: Although the power supply can withstand vibration tests of up to 5G, try to avoid severe vibration and impact.
9. Regular Inspection: Regularly check the status of the power supply, including checking for overheating, noise, or other abnormalities.
10. Follow EMC Guidelines: If the power supply will be used with sensitive electronic equipment, ensure proper electromagnetic compatibility (EMC) measures are followed.
11. Note Safety Standards: The LRS-150 complies with various international safety standards, and should be used in accordance with standards.
12. Avoid Use in Harsh Environments: Although the power supply has some environmental resistance, it should be avoided in extremely humid or dusty environments.
13. Be Aware of EMI Filtering: The LRS-150 power supply includes an EMI filter to reduce electromagnetic interference; use the product correctly according to the specifications.
14. Pay Attention to Size and Installation: When installing the power supply, ensure that the mechanical dimensions fit your system and that there is enough space for installation and maintenance.
Remember, these are general recommendations, and specific usage should refer to the product specifications and user manuals to ensure the correct and safe use of the LRS-150 power supply.more details,please contact us
GET A QUOTE